Independent distributor of active ICs, microcontrollers & semiconductors for OEM, EMS and distributors
PartVaneICs & Semiconductors

MAX6675 vs MAX31865: Type-K Thermocouple or PT100 RTD, and Why the MAX6675 Stops at 0 °C

2026-11-08 · PartVane Electronics

MAX6675 vs MAX31865: quick answer

These are not two accuracy grades of the same front end. The MAX6675 digitises a type-K thermocouple and reaches +1024 C but cannot read below 0 C; the MAX31865 digitises a platinum RTD from PT100 to PT1000 with 2-, 3- or 4-wire connections, reads below zero, and is specified to 0.5 C total accuracy. They are neither pin compatible nor software compatible, and the converter's own temperature grade differs: -20 to +85 C against -40 to +125 C.

ItemMAX6675ISA+ (ADI / Maxim)MAX31865ATP+ (ADI / Maxim)
SensorType-K thermocouple only; no J, T, E, N, R or SPlatinum RTD, 100 ohm to 1 kohm at 0 C (PT100 to PT1000)
Measurement range0 C to +1024 C; hot junction readable 0 C to +1023.75 CSet by the RTD; sub-zero readings are ordinary
Reads below 0 CNoYes
Resolution12-bit, 0.25 C per LSB15-bit ADC, 0.03125 C nominal
Accuracy spec8 LSB (2.0 C) for 0 C to +700 C at 3.3 V, T_A = +25 C; 17 LSB above +700 C0.5 C maximum total, 0.05 % of full scale, over all operating conditions
Cold-junction error+/-3.0 C over T_A = -20 C to +85 CNot applicable, no cold junction
Conversion time0.17 s typical, 0.22 s maximum21 ms maximum
InterfaceSPI-compatible, read only; 16-clock frame; no registers to writeSPI-compatible, configurable
Fault detectionOpen-thermocouple flag on bit D2; T- must be groundedProgrammable: open element, element shorted out of range, short across element, cable open and short
Input protectionT+/T- absolute maximum V_CC + 0.3 VOvervoltage faults as large as +/-45 V
Sensor wiringT+ and T-, with T- grounded2-, 3- or 4-wire
External parts0.1 uF decouplingR_REF reference resistor, 0.1 uF decoupling, C_I = 10 nF (PT1000) or 100 nF (PT100)
Supply3.0 V to 5.5 V, 0.7 mA typical / 1.5 mA maximumNot verified today; we do not quote it
Operating temperature of the IC-20 C to +85 C-40 C to +125 C (ATP and AAP)
Package8-pin SO20-pin TQFN-EP 5 x 5 mm (ATP); 20-pin SSOP (AAP)
Reel order codeMAX6675ISA+ (+ denotes lead-free package)MAX31865ATP+T; the plain ATP+ is not the reel code

MAX6675 column read from Analog Devices datasheet 19-2235 Rev 3 (6/21), re-opened 2026-11-08. MAX31865 column from our verified part record of datasheet 19-6478 Rev 3 (7/15), verified 2026-11-02; that PDF could not be downloaded on 2026-11-08, so it was not re-read. Degree equivalents of LSB figures are our arithmetic at 0.25 C per LSB.

Buy the parts compared here

Production quantities? Quote with real photos & date code in 2h

The MAX6675ISA+ and the MAX31865ATP+ get compared because both are Analog Devices (Maxim) temperature front ends with an SPI output, and both land on the same line of a BOM that just says “read a temperature over SPI”. That is where the similarity ends. These are not two accuracy grades of one part. They digitise two different sensors, and the sensor decision comes first: the MAX6675 reads a type-K thermocouple and nothing else, the MAX31865 reads a platinum resistance element and nothing else. They are neither pin compatible nor software compatible, and swapping one for the other means changing the sensor on the end of the cable.

Two different sensors, not two accuracy grades

A thermocouple is a pair of dissimilar wires that generates a small voltage proportional to the difference between its hot and cold ends. A platinum RTD is a resistor whose resistance rises predictably with temperature. Everything else in this comparison follows from that one difference. The thermocouple part has to measure its own board temperature to know what the cold end is doing, which is what “cold-junction compensation” means; the RTD part has to drive a known current through a known reference resistor and measure a ratio. One is a voltage problem, the other is a resistance problem, and the circuit around each is different.

The practical consequence for a buyer is that there is no such thing as upgrading from a MAX6675 to a MAX31865 on an existing board. The probe changes, the connector changes, the external parts change and the driver changes.

Quote MAX6675ISA+ for your build

Send the quantity: we reply within 24 hours with price, availability and photos of the actual parts with the date code. Samples and small batches welcome. Comparing both? Quote MAX31865ATP+ too.

Request Quote

The MAX6675 cannot read below 0 °C

This is the single most expensive thing to discover late. The MAX6675's specified measurement range is 0 °C to +1024 °C; the datasheet's detailed description puts the readable hot junction at 0 °C to +1023.75 °C, and an all-zero output word means 0 °C. There is no negative code. A type-K thermocouple itself happily goes well below freezing, but this converter will not report it.

The MAX31865 covers platinum RTDs from 100 Ω to 1 kΩ at 0 °C — PT100 through PT1000 — and is a resistance-to-digital converter, so sub-zero resistance values are ordinary readings for it. If the application is a freezer, a chiller, a cold chain logger or anything outdoors, the MAX6675 is disqualified before any accuracy discussion starts. If the application is a kiln, a reflow oven, an extruder or an exhaust, the MAX6675's 1000 °C-class range is the reason to pick it: a PT100 front end does not reach there.

Resolution is 0.25 °C; accuracy is not

The MAX6675 is a 12-bit converter resolving 0.25 °C per LSB. Its accuracy is specified in LSBs, and only over part of its range. Converting those LSB figures into degrees at 0.25 °C/LSB gives the table below.

Measured thermocouple temperatureError at VCC = 3.3 VError at VCC = 5 VSame error in °C (our arithmetic)
+700 °C, TA = +25 °C±5 LSB±6 LSB±1.25 °C / ±1.5 °C
0 °C to +700 °C, TA = +25 °C±8 LSB±9 LSB±2.0 °C / ±2.25 °C
+700 °C to +1000 °C, TA = +25 °C±17 LSB±19 LSB±4.25 °C / ±4.75 °C
Cold-junction compensation error, TA = −20 °C to +85 °C±3.0 °C±3.0 °C±3.0 °C (already in °C)

LSB figures are from Analog Devices datasheet 19-2235 Rev 3 (6/21). The degree column is our conversion at 0.25 °C per LSB, not a datasheet number. Note also that the datasheet marks these entries “guaranteed by design, not production tested”, and that it specifies 100 % test only at TA = +25 °C.

Two things fall out of that table. First, the widely quoted “8 LSB accuracy” applies to 0 °C to +700 °C only — above 700 °C the specification roughly doubles, and the part is sold with a +1024 °C headline. Second, the supply rail is part of the accuracy spec: every error entry is one LSB worse at 5 V than at 3.3 V.

The MAX31865 is specified the other way round, as a single number: 0.5 °C maximum total accuracy, equal to 0.05 % of full scale, over all operating conditions, with a 15-bit ADC and a nominal 0.03125 °C temperature resolution that varies with RTD nonlinearity. One number covering all conditions is much easier to design against than a table of LSB limits that only hold at +25 °C ambient.

Cold-junction compensation is where the MAX6675's error lives

The MAX6675 measures its own die temperature with an internal diode and corrects for it, modelling type-K as a straight 41 µV/°C line. That correction carries a ±3.0 °C error of its own across the device's −20 °C to +85 °C ambient range, and it only works if the chip really is at the same temperature as the cold junction. The datasheet says so directly: keep heat-generating components away from the MAX6675, use a large ground plane, and expect self-heating to degrade the reading.

That means a MAX6675 sitting next to a regulator, a motor driver or inside a sealed enclosure with a temperature gradient across it will read wrong in a way no calibration constant fixes, because the error moves with the board. An RTD front end has no cold junction at all, so this entire failure mode does not exist on the MAX31865.

The MAX6675 has no registers: what you solder is what you get

The MAX6675 interface is read-only. There is no register to write, no averaging setting, no filter selection, no fault mask — nothing to configure in system. Pulling CS low immediately aborts any conversion in progress and starts shifting data out; taking CS high starts a new conversion. That is the whole control surface.

The MAX31865 is a configurable device with programmable fault detection, which means firmware can set it up, read fault status and change behaviour in the field. If a product needs to change sampling behaviour after it ships, or needs to report why a reading is bad rather than just that it is, the MAX6675 cannot do it at any price.

Reading the MAX6675: 16 clocks, and three bits that are not temperature

A complete read is 16 clock cycles, data valid on the falling edge, at up to 4.3 MHz. Only twelve of those bits are the measurement.

BitContentWhat it means in firmware
D15Dummy sign bit, always zeroDiscard; it is not a sign bit you can use for negative temperatures
D14–D312-bit converted temperature, MSB firstMultiply by 0.25 to get °C
D2Open-thermocouple flagNormally low, goes high when the input is open — check it before trusting D14–D3
D1Device ID, lowUse as a sanity check that something is actually answering
D0Three-stateIgnore

One wiring detail decides whether the open-thermocouple detector works at all: T− must be grounded, with the ground connection made as close to the GND pin as possible. A floating T− leaves the only diagnostic bit on the part useless.

What the MAX31865 adds: fault detection and ±45 V input protection

Against the MAX6675's single open-circuit bit, the MAX31865 offers programmable detection of an open RTD element, an RTD shorted to an out-of-range voltage, and a short across the element, plus cable open and short conditions. Its inputs are protected against overvoltage faults as large as ±45 V.

For a sensor on a long cable in an industrial cabinet, that protection figure is often the deciding specification on its own. Sensor leads pick up whatever else is in the trunking, and a front end that survives ±45 V on its inputs is a different class of product from one whose inputs are rated to VCC + 0.3 V, which is what the MAX6675's absolute maximum table allows on T+ and T−.

The reference resistor and the input filter capacitor

The MAX31865 needs external parts the MAX6675 does not, and one of them is a documented trap. The reference resistor RREF sets the measurement's sensitivity and feeds fully differential VREF inputs, so its tolerance and tempco go directly into the result — this is the part of the circuit a cost reduction must never touch. The input capacitor CI in the 4-wire application circuit is 10 nF for a 1 kΩ RTD and 100 nF for a 100 Ω RTD.

External partsMAX6675ISA+MAX31865ATP+
Supply decoupling0.1 µF VCC to GND0.1 µF
Reference resistorNoneRREF required; sets sensitivity
Input filter capacitorNone specifiedCI = 10 nF (PT1000) or 100 nF (PT100)
Sensor wiringT+ and T−, T− grounded2-, 3- or 4-wire

Copying a PT100 reference design onto a PT1000 board and leaving the 100 nF in place moves the input filter corner by a factor of ten. It will still read; it will read slowly and wrongly in the presence of noise, which is the hardest kind of fault to find.

2-, 3- and 4-wire RTDs: where lead resistance goes

The MAX31865 supports 2-, 3- and 4-wire sensor connections, and that choice is about cable resistance, not convenience. In a 2-wire hookup the resistance of the leads adds directly to the element and shows up as a temperature offset; 3-wire cancels most of it; 4-wire removes it from the measurement. A PT100 changes by roughly 0.39 Ω/°C near 0 °C — that is the IEC 60751 sensor standard, not a MAX31865 datasheet figure — so a couple of ohms of lead resistance is degrees of error — which is also the practical argument for PT1000 on long runs, since the same lead resistance is a tenth of the signal. The MAX6675 has no equivalent decision: thermocouple extension wire has its own rules, but there is no lead-compensation setting on the part.

Conversion time: 0.17–0.22 s against 21 ms

The MAX6675 takes 0.17 s typical, 0.22 s maximum per conversion. The MAX31865's conversion time is 21 ms maximum. That is roughly an order of magnitude, and it matters in two places: a control loop that needs to react, and a multi-channel system where one SPI bus serves many sensors. Five MAX6675 channels polled in turn is about a second of latency on the slowest channel. It is worth being blunt about this, because a thermal process is usually slow enough that 0.2 s is irrelevant — for an oven it is; for a closed-loop heater on a small thermal mass it is not.

The converter's own temperature grade is the quiet dealbreaker

The MAX6675ISA is specified from −20 °C to +85 °C. That is the ambient range of the chip, not the probe, and it is narrower than most industrial parts. Both MAX31865 order codes, ATP and AAP, are specified −40 °C to +125 °C.

A board that measures 600 °C through a probe but must itself survive an unheated cabinet at −30 °C is outside the MAX6675's specification even though the measurement is well inside its range. This is the same class of mistake we have written about in other families, where a single letter in the order code is the whole temperature grade — see TCAN1042 vs TCAN1042H vs HGV for the CAN transceiver version of it.

Supply, interface and board-level numbers

The MAX6675 runs from 3.0 V to 5.5 V drawing 0.7 mA typical, 1.5 mA maximum, with a power-on reset threshold of 1 V to 2.5 V on a rising supply, 50 mV of hysteresis, a thermocouple input impedance of 60 kΩ and a conversion constant of 10.25 µV/LSB. Its logic thresholds track the rail (0.3 × VCC low, 0.7 × VCC high), so a 5 V-powered MAX6675 driven by 3.3 V logic needs checking: 0.7 × 5 V is 3.5 V, above a 3.3 V output. In the 8-pin SO package continuous dissipation is 471 mW at TA = +70 °C, derating 5.88 mW/°C above that, and ESD protection is ±2000 V HBM.

Its pinout is short enough to reproduce in full, which also shows why there is nothing to configure: there is no data-in pin.

PinNameFunction
1GNDGround
2T−Alumel lead; must be connected to ground externally
3T+Chromel lead
4VCCPositive supply, bypass 0.1 µF to GND
5SCKSerial clock input
6CSChip select, low enables the interface
7SOSerial data output
8N.C.No connection

Order codes and packages

Both families have order-code detail that is easy to get wrong on a purchase order.

Order codePackageNote
MAX6675ISA+8-pin SO (Maxim code S8+2, outline 21-0041)The + denotes the lead-free, RoHS-compliant package
MAX31865ATP+20-pin TQFN with exposed pad, 5 mm × 5 mm (T2055+5, outline 21-0140)Exposed pad must be handled on the layout
MAX31865AAP+20-pin SSOP (A20+1, outline 21-0056)Same die, hand-solderable package, same −40 °C to +125 °C grade
MAX31865ATP+TSame TQFN, tape and reelThe trailing T is the reel code — MAX31865ATP+ on its own is not the reel part number

If a quote comes back against MAX31865ATP+ and the line needs reel packaging for a pick-and-place machine, say so explicitly; this is a frequent source of a correct part arriving in the wrong packaging. Send both the order code and the packaging you need on the RFQ and we will confirm it against stock.

Which one to put on the BOM

Choose the MAX6675ISA+ when the measurement is above 0 °C and goes high — kilns, ovens, extruders, exhaust gas, soldering equipment — the probe is already a type-K, a couple of degrees is good enough, the converter itself lives in a benign 0 °C to +70 °C environment, and the simplest possible driver is an advantage. Choose the MAX31865ATP+ when readings go below zero, when you need 0.5 °C-class total accuracy with one specification that holds over all conditions, when the sensor is on a long cable and needs fault diagnostics and ±45 V input protection, when 3- or 4-wire lead compensation is required, or when the board itself must be qualified to −40 °C or +125 °C.

If the decision is really about who does the ADC work rather than about thermocouples, the comparison to read next is an analogue thermistor against a digital sensor — the NTCLE100E3103JB0 against the DS18B20+ — where the trade is cost and sampling freedom against timing and calibration.

What we did not verify

We re-read the MAX6675 datasheet (19-2235 Rev 3, 6/21) in full for this article, and every MAX6675 figure above is from it, with the degree conversions in the accuracy table marked as our own arithmetic. The MAX31865 figures come from our verified part record built from datasheet 19-6478 Rev 3 (7/15); we could not re-open that PDF today — the download failed repeatedly — so treat the MAX31865 column as our record of that revision rather than as a fresh reading. Specifically not verified: the MAX31865's supply voltage range, its SPI clock limit, its notch-filter options, and its quiescent current, none of which we quote here. Lifecycle status is not verified for either part: the MAX6675 datasheet carries a notice asking buyers to confirm production status with Analog Devices, and the MAX31865 datasheet states no lifecycle status. We have not bench-tested either device. For a firm stock, price and date-code position on a specific order code, send the line through the RFQ form.

Sources

Parts in This Article

More Guides

Request a Quote